Polycom Vortex EF2201 Command List page 30

Rs-232 command set
Hide thumbs Also See for Vortex EF2201:
Table of Contents

Advertisement

This error occurs when the user has attempted to utilize more variable DSP resources
than are available. This may occur if too many matrix crosspoints are unmuted or too
ERROR#060
many parametric EQ filters are enabled. The
current percentage utilization of DSP resources.
This error occurs as a result of a macro or preset execution command (PRESETX,
PRESETQ, MACROX, MACROQ). It indicates that the macro or preset requested was
ERROR#070
empty.
This error occurs as a result of a
PRESETW
ERROR#071
not allowed. In the case of PRESETK, it indicates that an attempt was made to delete
a factory preset, which is not allowed.
This error occurs as a result of a
ERROR#072
commands in the preset had errors during execution.
This error occurs as a result of a
ERROR#073
commands in the macro. The limit is 256 commands per macro.
This error occurs in response to a
ERROR#074
If the command written to the macro or logic pin is illegal, then this error occurs.
This error occurs when a command attempts to write non-volatile memory, but non-
ERROR#075
volatile memory is password protected via NVLOCK.
This error occurs when attempting to add a macro command (either during an upload
or while writing a single macro) and the Vortex runs out of room in non-volatile
ERROR#076
memory. As a result, the entire macro is discarded. If this occurs during an upload,
all previous macros (before the one that caused the error) are written successfully.
This error occurs when attempting to add a command to a macro, but the Vortex is
not in the process of writing a macro. This may happen if you forget to do a MACROS
ERROR#077
or UMACROS command, or if you had an ERROR#076 and continued trying to add
commands.
This error indicates an EF Bus hardware handshaking error. This could happen if
bussed units are not powered on simultaneously. Powering the units up
ERROR#090
simultaneously should remove the error.
This error indicates an EF Bus software handshaking error. This could happen if
bussed units are not powered on simultaneously. Powering the units up
ERROR#091
simultaneously should remove the error.
This error indicates an EF Bus ID conflict. See the Vortex user manual for information
ERROR#092
on valid device IDs.
This command is a boolean command. See
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example
Description
T01ERROR1 Enable error messages.
it indicates that an attempt was made to write to a factory preset, which is
Section 6.1
Status Message
T01ERROR1
DSPLOAD
or
PRESETW
PRESETK
command. It indicates that one or more
PRESETQ
command when there are already too many
MACROA
or a logic pin (LIA, LIH, etc.) command.
MACROA
for more information on this type of command.
command can query the
command. In the case of