This command is a boolean command. See
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description
T01AHLD1 Enable loop drop based auto hangup mode. T01AHLD1
T01AHLD0 Disable loop drop based auto hangup mode. T01AHLD0
T01AHLD2 Toggle loop drop based auto hangup mode.
T01AHLD? Query auto hangup mode.
8.9. AMNOMAT -- Select NOM Attenuation on Each Output
This command enables, disables, or queries NOM attenuation for the specified output . (A, B, T). NOM
attenuation is calculated as 10*log(Number of Open Microphones).
Remember that even though there are no microphones on this device, other microphones can be
brought in via the W, X, Y, and Z busses. These signals will have NOM information carried with them
from the other devices, which is why NOM attenuation is provided at the outputs.
This command is a channel boolean command. See
this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will
be restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
Enable NOM attenuation on
T01AMNOMATA1
output A.
Disable NOM attenuation on
T01AMNOMATA0
output A.
Toggle NOM attenuation status on
T01AMNOMATB2
output B.
Query NOM attenuation status of
T01AMNOMATB?
output B.
Enable NOM attenuation on all
T01AMNOMAT*1
outputs (A, B).
Disable NOM attenuation on all
T01AMNOMAT*0
outputs (A, B).
Section 6.1
for more information on this type of command.
Status Message
T01AHLDx, where x is 0 or 1 depending on
the current state of the loop drop based auto
hangup mode.
T01AHLDx, where x is 0 or 1 depending on
the current state of the loop drop based auto
hangup mode.
Section 6.3
and
Status Message
T01AMNOMATA1
T01AMNOMATA0
T01AMNOMATBx, where x is either 0 or 1
depending on the current mute status of NOM
attenuation on the ouptut.
T01AMNOMATBx, where x is either 0 or 1
depending on the current NOM attenuation
status of the output.
T01AMNOMAT*11
T01AMNOMAT*00
Section 6.1
for more information on