Table of Contents

Advertisement

EventSpot 1600 Q4
Channel 6 – Control functions
0–15
No function
16–45
Dimmer fast
46–75
Dimmer slow
76–105
Linear curve
106–135
Square curve
136–165
Inv. Square curve
166–195
S-type curve
196-225
Eco ON
226-255
Eco OFF
Channel 7 – Red Dimmer intensity
0–255
Gradual adjustment Red, from dark to brightest
Channel 8 – Green Dimmer intensity
0–255
Gradual adjustment Green, from dark to brightest
Channel 9 – Blue Dimmer intensity
0–255
Gradual adjustment Blue, from dark to brightest
Channel 10 – White Dimmer intensity
0–255
Gradual adjustment White, from dark to brightest

Maintenance

The operator has to make sure that safety-related and machine-technical installations are to be
inspected by an expert after every year in the course of an acceptance test.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01) All screws used for installing the device or parts of the device have to be tightly connected and
must not be corroded.
02) There may not be any deformations on housings, fixations and installation spots.
03) Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
04) The electric power supply cables must not show any damages or material fatigue.
The EventSpot 1600 Q4 requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture's light output will be significantly reduced. Disconnect the mains power supply, and
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and
a soft cloth. Do not use alcohol or solvents.
The front lens will require weekly cleaning, as smoke fluid tends to build up residues, reducing the light
output very quickly.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying
electric power.
Ordercode: 44050
Wait for at least 2 seconds for the functions to activate
CH1 must be set between 1–255
CH1 must be set between 1–255
CH1 must be set between 1–255
CH1 must be set between 1–255