  • Page 1 USER MANUAL ENGLISH Cameleon Flood 6 Q4 Tour Product code: 42682 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2 Cameleon Flood 6 Q4 Tour Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
  • Page 3: Table Of Contents

    Cameleon Flood 6 Q4 Tour Table of contents Introduction ................................4 Before Using the Product ..........................4 Intended Use ............................... 4 Product Lifespan ..............................4 LEDs Lifespan ............................... 4 Text Conventions ..............................4 Symbols and Signal Words ..........................5 Symbols on the Information Label ........................5 Safety ..................................
  • Page 4 Cameleon Flood 6 Q4 Tour Curves Select ............................25 Dimmer Speed ............................26 DMX Fail ..............................26 DMX Sync .............................26 Lock ...............................27 Factory ..............................27 Information ..............................27 DMX Channels ..............................28 4 Channels, 6 Channels, 10 Channels ....................28 Supported RDM PIDs (Parameter IDs) ......................29 Remote Control ..............................30 Auto................................32...
  • Page 5: Introduction

    After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec Cameleon Flood 6 Q4 Tour ● Schuko to pro power True1 cable (1,5 m) ●...
  • Page 6: Symbols And Signal Words

    Cameleon Flood 6 Q4 Tour Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in DANGER death or serious injury.
  • Page 7: Safety

    Cameleon Flood 6 Q4 Tour Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual.
  • Page 8 Cameleon Flood 6 Q4 Tour ● Do not connect the cables from above the connectors, if the device is installed outdoors. Make a ‘drip loop’ in the cable so that rain water cannot enter the device. WARNING Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy.
  • Page 9: Requirements For The User

    Cameleon Flood 6 Q4 Tour Attention Before each use, examine the device visually for any defects. Make sure that: ● All screws used for installing the device or parts of the device are tightly fastened and are not corroded. ●...
  • Page 10: Description Of The Device

    Cameleon Flood 6 Q4 Tour Description of the Device The Showtec Cameleon Flood 6 Q4 Tour is an IP65-rated outdoor wall washer. It is equipped with 6 x 4-in-1 RGBW LEDs. Front View 01) Infrared sensor 02) 6 x 5 W RGBW LEDs 03) Mounting bracket Fig.
  • Page 11: Product Specifications

    Cameleon Flood 6 Q4 Tour Product Specifications Model: Cameleon Flood 6 Q4 Tour Electrical: Input voltage: 100–240 V AC, 50/60 Hz Power consumption: 38 W Physical: Dimensions: 220 x 83 x 165 mm (L x W x H) (including bracket)
  • Page 12: Dimensions

    Cameleon Flood 6 Q4 Tour Dimensions Fig. 04 Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons.
  • Page 13: Rigging

    Cameleon Flood 6 Q4 Tour Rigging The device can be positioned on a flat surface or mounted to a truss or other rigging structure. Make sure that all loads are within the pre-determined limits of the supporting structure. CAUTION Restrict the access under the work area during rigging and/or derigging.
  • Page 14: Connecting To Power Supply

    Cameleon Flood 6 Q4 Tour Connecting to Power Supply DANGER Electric shock caused by short-circuit The device accepts AC mains power at 100–240 V and 50/60 Hz. Do not supply power at any other voltage or frequency to the device.
  • Page 15: Setup

    Disconnect power supply before connecting or disconnecting data cables. Stand-alone Setup When the Cameleon Flood 6 Q4 Tour is not connected to a controller or to other devices, it functions as a stand-alone device. For more information about the control modes, refer to 6.2. Control Modes on page 17.
  • Page 16: Dmx Cables

    Cameleon Flood 6 Q4 Tour DMX Cables Shielded twisted-pair cables with 3-pin XLR connectors must be used for reliable DMX connection. You can purchase DMX cables directly from your Highlite International dealer or make your own cables. If you use XLR audio cables for DMX data transmission, this may lead to signal degradation and unreliable operation of the DMX network.
  • Page 17: Dmx Linking

    In a setup with multiple devices, make sure that you set the DMX starting address of each device correctly. The Cameleon Flood 6 Q4 Tour has 3 personalities: 4, 6 or 10 channels. If you want to connect multiple devices on one data link and use them in 10-channel mode, for...
  • Page 18: Operation

    Control Modes The Cameleon Flood 6 Q4 Tour can be operated with a DMX controller, or without a DMX controller as a stand-alone device or in a master/slave setup.
  • Page 19: Control Panel

    Cameleon Flood 6 Q4 Tour Control Panel A) OLED display DOWN button C) UP button D) SET button MODE button Fig. 10 ● Use the MODE button to exit the current submenu and to return to the Main Menu. ●...
  • Page 20: Menu Overview

    Cameleon Flood 6 Q4 Tour Menu Overview Product code: 42682...
  • Page 21 Cameleon Flood 6 Q4 Tour Product code: 42682...
  • Page 22: Main Menu Options

    Cameleon Flood 6 Q4 Tour Main Menu Options Upon start-up, the display will show the current software version and the temperature. The main menu has the following options: ● Touch the UP/DOWN buttons to navigate through the main menu. ●...
  • Page 23: Address

    Cameleon Flood 6 Q4 Tour Address In this menu you can set the desired DMX starting address. 01) Touch the UP/DOWN buttons to set the desired DMX address. The adjustment range is 001–512. 02) Touch the SET button to confirm your choice.
  • Page 24: Auto

    Cameleon Flood 6 Q4 Tour Auto In this menu you can set Auto mode. 01) While in the main menu, touch the UP/DOWN buttons to choose AUTO. 02) Touch the SET button to enter the menu. The display will show: 03) Touch the UP/DOWN buttons to choose YES (to start the auto show) or NO (to return to the previous screen.
  • Page 25: Programs 02-16

    Cameleon Flood 6 Q4 Tour Program 01 01) If you choose program 01, the display will show: Touch the UP/DOWN buttons to choose one of the 2 options: ● COLOR ● STROBE Touch the SET button to enter the desired menu.
  • Page 26: Settings

    Cameleon Flood 6 Q4 Tour Settings In this menu you can adjust the device’s settings. 01) While in the main menu, touch the UP/DOWN buttons to choose SETTINGS. 02) Touch the SET button to enter the menu. The display will show: 03) Touch the UP/DOWN buttons to choose one of the 6 submenus: ●...
  • Page 27: Dimmer Speed

    Cameleon Flood 6 Q4 Tour Dimmer Speed In this menu you can set the dimmer speed. 01) Touch the UP/DOWN buttons to select FAST or SMOOTH. 02) Touch the SET button to confirm your choice. DMX Fail In this menu you can set the device’s behavior in case of a DMX failure.
  • Page 28: Lock

    Cameleon Flood 6 Q4 Tour Lock In this menu you can set the safety lock, restricting access to the main menu. 01) Touch the UP/DOWN buttons to select one of the 2 options: ● ON: when no button is pressed within 30 seconds, the device’s main menu will be locked.
  • Page 29: Dmx Channels

    Cameleon Flood 6 Q4 Tour DMX Channels 4 Channels, 6 Channels, 10 Channels 4 CH 6 CH 10 CH Function Value Setting Master Dimmer 000–255 From low to high intensity (0–100 %) 000–010 No function Linear Strobe 011–255 From` low to high frequency (0–15 Hz) 000–010...
  • Page 30: Supported Rdm Pids (Parameter Ids)

    Cameleon Flood 6 Q4 Tour 4 CH 6 CH 10 CH Function Value Setting 112–127 Program 7 128–143 Program 8 144–159 Program 9 160–175 Program 10 176–191 Program 11 192–207 Program 12 208–223 Program 13 224–239 Program 14 240–255 Program 15 Program Speed 000–255...
  • Page 31: Remote Control

    Cameleon Flood 6 Q4 Tour Remote Control The device can be controlled with an IR remote control (44002). DANGER Do not ingest battery, chemical burn hazard The remote control contains a coin cell battery. If the coin cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
  • Page 32 Cameleon Flood 6 Q4 Tour To operate the device with the IR remote control, point the remote control to the infrared sensor (01). The remote control will work only if the device is already operating in Auto, Built-in Programs or Manual mode.
  • Page 33: Auto

    Cameleon Flood 6 Q4 Tour Button Function Description Green Activates Green LEDs Blue Activates Blue LEDs No function White Activates White LEDs Color 14 Activates color 14 (R 000; G 255; B 255; W 000) Color 22 Activates color 22 (R 160; G 000; B 255; W 000) Color 23 Activates color 23 (R 255;...
  • Page 34: Program Speed

    Cameleon Flood 6 Q4 Tour Program Speed Press the button to set the program speed. Press the buttons to increase/decrease the program speed. The adjustment range is 1– 100, from slow to fast. Note: If you select program 1 and start adjusting the program speed, the device will automatically switch to program 2.
  • Page 35: Troubleshooting

    Cameleon Flood 6 Q4 Tour Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
  • Page 36: Maintenance

    Cameleon Flood 6 Q4 Tour Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. WARNING Risk of burns due to hot surface Allow the device to cool down for at least 15 minutes before servicing or cleaning.
  • Page 37: Basic Cleaning Instructions

    Cameleon Flood 6 Q4 Tour Basic Cleaning Instructions The external lens of the device must be cleaned periodically in order to optimize the light output. The cleaning schedule depends on the conditions at the site where the device is installed. When smoke or fog machines are used at the site, the device will need more frequent cleaning.
  • Page 38: Deinstallation, Transportation And Storage

    Cameleon Flood 6 Q4 Tour Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.
  • Page 39 Cameleon Flood 6 Q4 Tour Product code: 42682...