Troubleshooting
CAUTION!
Only authrized service personnel is allowwed to perform repair work!
Operating staff is only allowed to remove such malfunctions which are
obviously caused by incorrect operating!
DANGER ELECTRIC SHOCK!
Prior to performing any repair work, secure the unit against accidental
reconnection.
Error messages
Put the mains disconnection switch into position "0".
Put the lock into the openings of the switch.
Close the lock.
Error
Possible cause and correction
code
Wind-flag does not turn on
E01
Check wind-flag and windflag terminal.
Facial filter defective or missing.
E02
Replace or assemble facial filter.
Sunbed acrylic open.
E03
Close sunbed acrylicn.
Front cover open. (not assigned on all units)
E04
Check front cover for correct fit.
Emergency stop button activated (optional).
E05
Unlock emergency stop button.
SunFresh container empty. (optional)
E06
Refill SunFresh container with distilled water.
Condensation water container full. (optional)
E07
Empty the condensation water container
Communication error.
E08
Check cable/terminal to the control panel.