Storage

If you intend not to operate the sunbed for a considerable
time, you should store the equipment at a dry place,
protected from dust and corrosion.
Switch off the mains disconnection switch. Secure with
lock and key against accidental and unauthorized re-
activation of power supply.
Cover the sunbed with lint—free cloth or appropriate
cover material to protect it against dust and dirt.

Re-use

If you want to operate the sunbed after storage again,
remove the cover material.
Clean the sunbed as described on page 37.
Remove the lock and connect to power supply by turning
on the mains disconnection switch.
Perform daily maintenance inspection as described on
page 26.
ORIGINAL DR. MÜLLER HIGH PERFORMANCE TANNING EQUIPMENT
37

Troubleshooting

Malfunction
Unit does not start when
Timer device is activated.
Low-pressure lamp -
flickering.
Unit gets to hot.
One or more low-pressure
lamps in the top or sunbed
do not light up.
One or more HID quartz
lamps (facial lamps) do not
light up.

Disposal

The sunbed must be properly disassembled when taken
finally out of operation.
Properly dispose of freezing liquid when you dispose of A/C
unit and observe all applicable evironmental standards and
regulations.
All components of the sunbed must be sorted and re-cycled
according to all applicable environmental standards and
regulations.
Please contact your local authorities for applicable
environmental standards and regulations and due
procedures for disposal.
Possible cause and
elimination
No power supply.
Check fuses.
Starter defective.
Replace starter.
Fresh air supply and outlet of
exhaust air in the room may not
be sufficient.
Check air flow and remove
obstacles if necessary.
Low-pressure lamp not
correctly locked into
lampholder.
Instal low-pressure lamp
correctly.
Low-pressure lamp defective.
Replace low-pressure lamp.
HID quartz lamp defective.
Replace HID quartz lamp.
Ignitor for HID quartz lamp
defective.
Replace ignitor.