Technical DataFehler! Textmarke nicht definiert.
Dimensions
Length
Depth
Height, top canopy closed
Height, top canopy open
Entry level
Weight
Cpl. unit without AC
Sunbed
Top canopy
Ballast tray
AC unit (optional)
Lamp configuration
Top canopy
(Standard Version)
Side column
Sunbed
Facials
Air volume and fresh
Required opening for fresh air entry on the
air supply on the site
site
Exhaust air volume
Main exhaust air stack
Electrical connection
Voltage
(only for EU
Power intake without AC unit
standard versions)
Power intake with AC unit
Fusage on the site
Required supply cable gauge for flexible
cable Europa HO5VV-F
Technical requirements at site of installation
Room size for operation and maintenance
Floor, level, load capacity
Ambient temperature
Relative humidity
94"
58"
54"
70"
24"
885 lbs.
265 lbs.
310 lbs.
310 lbs.
25 lbs.
19 x 71" "Original Dr. Müller" low-pressure
lamps (160 W reflector lamps)
8 x 71" "Original Dr. Müller" low-
pressure lamps (160 W reflector lamps)
19 x 71" "Original Dr. Müller" low-
pressure lamps (160 W reflector lamps)
4 x "Original Dr. Müller" high-pressure lamps
(650 W adjustable)
diameter 12"
1300 CFM
diameter 12", length max. 12'
240 V / 50 Hz / 3 ph NPE
46 amps
52 amps
60 amp 3 phase
6 guage - 3 hot + 1 ground
9' x 9'
365 lbs. psqf.
+50 °F through +86 °F
max. 65%
15