EBARA Oil Smart Pump System
Oil Smart
®
Pump System – Installation Instructions
1. Inspection: Your system has been carefully packaged to prevent damage during
shipping. However, occasional damage does occur due to rough handling. Carefully
inspect all parts of the system that could cause it to fail.
2. Refer to the pump installation instructions on page 9 to begin. After completing the
pump installation steps, continue here.
3. Caution: To maintain the NEMA 4X rating, make all wiring connections with seal tight
cable grips or conduit connections to be supplied by end user.
4. Determine mounting location for control panel. Mount panel using mounting feet supplied.
5. Determine hole location on panel for liquid-tight or conduit connections. Attach connectors
and conduits.
6. It is important that the alarm circuit is independent of the pump to assure that the
alarm will activate if pump circuit fails.
7. Run pump cable, Liquid Smart® cable, and Oil Smart® cable through conduit. Make
field connections as shown on wiring diagram (See page XX).
8. Run power line conductor through conduit. Wire to terminals per enclose schematic.
Branch circuit protection to be provided by end-user.
9. For 1-1/2‰ pipe: Attach the Oil Smart® Pump Switch and Oil Smart® Liquid Alarm
Switch to the Quick Mount Brackets using the screws and nuts provided. Snap the
pump switch bracket onto the discharge pipe with the end of the long sensor 2‰
above the top of the pump. Snap the alarm bracket onto the discharge pipe with sensor
end 2‰ above the pump switch „on‰ position. Place hose clamps under the quick
mount brackets as a reference locator for the switch. Mount switches clear of the
basin inlet, so they will stay clean. Note: Keep sensors 1‰ to 2‰ away from any metallic
material.
10. For other than 1-1/2‰ pipe: Attach the Oil Smart® Pump Switch and Oil Smart®
Liquid Alarm Switch to the universal bracket. Place the supplied hose clamp through
the slots in the bracket before mounting the switch with the screws and nuts provided.
Clamp the Oil Smart® Pump Switch to the discharge pipe with the end of the long
sensor 2‰ above the top of the pump. Attach the Oil Smart® Liquid Alarm Switch onto
the discharge pipe with the sensor end 2‰ above the pump switch „on‰ position.
Mount switches clear of the basin inlet, so they will stay clean. Note: Keep sensors 1‰
to 2‰ away from any metallic material.
Start up:
1. When the power is applied, the red power light locate on the white front swing panel
shall light.
2. The Pump HOA Switch shall be placed to the A (auto) position to ensure the system
will pump. The pump can be tested or turned on manually if the HOA switch is in the H
(Hand-Manual) position.
To test the alarm circuit, push the test button on the front panel, the audible alarm shall
sound and the high red beacon will light.
Service:
Caution: Before checking electrical connections within the control or attempting to replace
any components, turn off all branch circuits supplying power to the main control panel.
EBARA Pumps Americas Corporation
www.pumpsebara.com
(t) 803 327-5005 • (f) 803 327-5097