2.8 Resource Programming

[800] SMDR Incoming / Outgoing Call Log Printout

Description
Used to determine which calls will produce a Station Message Detail Recording (SMDR)
printout.
Selection
• Outgoing calls: All (all calls) / Toll (toll calls only) / Off (no printing)
• Incoming calls: On (all calls) / Off (no printing)
Default
Outgoing calls – All; Incoming calls – On
Programming
1.
Enter 800.
Display: Duration Log
2.
Press NEXT to programme outgoing calls.
Display: Outgoing:All
3.
Keep pressing SELECT until the desired selection is displayed.
4.
Press STORE.
5.
Press NEXT to programme incoming calls.
Display: Incoming:On
6.
Keep pressing SELECT until the desired selection is displayed.
7.
Press STORE.
8.
Press END.
Conditions
• It is necessary to connect a printer to the Serial Interface (RS-232C) port provided on the
system.
• After connecting a printer, do not press the RETURN key, if provided on the printer, within
10 seconds. Otherwise, the usage of the Serial Interface port is changed to system
programming and printing will not occur.
• If "Toll" is selected, the system will print out all the calls starting from the numbers stored
in programmes [301-305] TRS Denied Code Entry for Levels 2 through 6.
General Programming
2.8 Resource Programming
187