5.2 System Programming
[109] Expansion Unit Type
Description
Assigns the type of expansion units to be used in the system.
This allows the system to identify the unit in each expansion unit location.
Selection
KX-TD816
• Areas 1; 2 = C (4 CO) / S1 (2 S0) / S2 (6 S0) / EM (4 E&M) / E (EXT) / D (No Use)
KX-TD1232
• Master / Slave
• Areas 1; 2; 3 = C (4 CO) / S1 (2 S0) / S2 (6 S0) / S3 (1 PRI) / EM (4 E&M) / E1 (8
EXT1) / E2 (8 EXT2) / D (No Use)
(Master system only: S3, E1 and E2 for the KX-TD144 or KX-TD146)
Default
KX-TD816: C;E
KX-TD1232: Master and Slave – C;E1;E2
Programming
KX-TD816
1.
Enter 109.
Display: Expansion Card
2.
Press NEXT.
Display example: Master:C ;E
3.
Keep pressing SELECT until the desired selection in Area 1 is displayed.
4.
Press
5.
Keep pressing SELECT until the desired selection in the Area 2 is displayed.
6.
Press STORE.
7.
Press END.
KX-TD1232
1.
Enter 109.
Display: Expansion Card
2.
Press NEXT to programme the Master System.
To programme "Slave", press NEXT again.
Display example: Master:C ;E1;E2
340
to programme Area 2, if required.
DECT Programming