ELECTRO FREEZE
6.2
Disassembly Instructions
The following accessories shipped with the freezer are necessary for cleaning,
sanitizing, and disassembly/assembly:
Figure 7-2
1. If there is product in the freezer, refer
to Closing Procedures, Draining
Product, Section 9.1.
2. Remove the four hand knobs (figure
6-2, item 2) and pull the dispensing
door (1) straight out.
3. Remove the ball knob (6), nut (5),
air bleed plug (4) and valve outlet (7)
from the door (1).
4. Remove the piston assembly (10, 11,
12, 13) and spring (9) by pushing the
piston rod (13) through the back of the
door (1).
14
Models 876, 876B, 876C, 876RH, 876BRH, 876CRH & 875 Batch
CAUTION
To avoid electrical shock or
contact with moving parts,
make sure all switches are in
the "OFF" position and that
the main power supply is
disconnected.
CAUTION
To prevent bacteria growth,
remove all O-rings when
cleaning. Failure to do so could
create a health hazard.
5. Remove the O-rings (11) from the
piston and O-ring (12) from the piston
rod. Remove the O-ring (8) from the
valve outlet (7). Remove two O-rings
(3) from the air bleed plug (4).
6. Remove the door bushing (15) from
the door (1) or end of the beater.
7. Remove the door quad ring (14) from
the face of the freezer.
184633