6 OPERATION
Circuit Breaker: 20A circuit breaker
1
that protects the Generator and
receptacles from overloading
2
120VAC GFCI Receptacles: Two
duplex 120VAC/20A GFCI receptacles
(NEMA #5-20)
3
240VAC Receptacle: One
240VAC/50A receptacle (NEMA #6-
50R)
Grounding Terminal: Used to have
4
the unit grounded through a grounding
wire (not included)
5
Welder Power Switch: Used to turn
the welder ON or OFF
Amperage/ARC FORCE Control:
6
Knob used to adjust the output current
of the welder from 20A to 150A or the
ARC FORCE between -10 and 10
Amperage/ARC FORCE Selection:
7
Push button used to switch between
output current or Arc Force
adjustments. The digital display will
show the corresponding setting value
6.3

Connecting the EDW to ground

WARNING!
GFCI receptacles will not protect from electric shock if the machine is not grounded.
NOTE!
The auxiliary power outlets (120/240VAC) are not intended to power sensitive electronic
equipment without the addition of an appropriate line conditioner and surge protector
(both not included). Sensitive electronic equipment should be operated on approved
inverter-type generators or pure sine wave generators
The engine driven welder must be properly grounded before use to prevent electric shock and
static electricity. This should be performed by a qualified electrician.
Connect the grounding cable (2) between equipment ground terminal (1) to metal frame or trailer
(3). Use #8 AWG or larger insulated copper wire.
0463 905 001
ARC FORCE Indication: This light is lit
8
when the ARC FORCE function is
selected
9
Amperage Indication: This light is lit
when the amperage setting is selected
10
Fault indicator: The light is lit when over
temperature occurs and it automatically
off when the temperature cools down
ON/OFF Welder Indication: This light is
11
lit when the welder is turned ON and is off
when the welder is turned OFF
12
Digital Display: It displays the settings
values for the output current and the ARC
FORCE function. When welding, it
displays the measured values
Negative welding terminal: Return cable
13
Positive welding terminal: Welding
14
cable
- 30 -