6 OPERATION
Grounding the EDW to a trailer or truck
1
Equipment grounding terminal
2
Grounding Cable (Not Supplied)
6.4

Connecting output terminals

The Ruffian ES 150G EDW is a DC (direct current) power source for STICK welding has Positive
(+) and Negative (-) terminals for welding and return cables, in most cases the connection as
follows:
Connect the return cable to the negative terminal on the power source. Secure the return cable's
contact clamp to the workpiece, and make sure that there is a good contact between the
workpiece and the output for the return cable on the power source.
NOTE!
The polarity of the welding cables depends on the type of electrode and their
specifications. Before use, refer electrode's data sheet.
6.5

Selecting and preparing welding cables

Required copper gauge based on total length of cable leads in the circuit
100 Ft or less
Welding
Current
(A)
10% to
60%
4 AWG
100
3 AWG
150
NOTE!
Weld cable size (AWG) is based on either 4 volts or less drop or a current density of not
more than 300 circular mils per ampere. Use weld cable with insulation rating equal to or
greater than the open-circuit voltage of the unit.
0463 905 001
3
Total length of cable leads in the circuit
150 Ft 200 Ft
60% to
100%
4 AWG 4 AWG 3 AWG
3 AWG 2 AWG 1 AWG 1/0 AWG
- 31 -
Metal Frame or trailer
250 Ft
300 Ft
Duty Cycle
10% to 100%
2 AWG
1 AWG
2/0 AWG
350 Ft
400 Ft
1/0 AWG
1/0 AWG
3/0 AWG
3/0 AWG
© ESAB AB 2022