18. Technical data

INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity. Remove the drawer
(see Overview > Storage for details).
COUNTRY OF DESTINATION: USA, Canada, Mexico.
Connections
Electric Supply
Electric Rating
Branch Circuit Protection
Connection Type
Maximum total electric load 240 V
* Load demand diversity calculation according to NFPA 70 article 220. Note: The
maximum input at any time is given as both ovens fanned and broiler, plus cooling fan.
Gas Connection
Dimensions
Overall height
Overall width
Overall depth
Minimum space above cooktop
Weight (unpacked)
Ratings
Oven
Fan element
Top element
Browning element
Bottom element
Gas Top
Centre burners
Larger burners
Right-hand front burner
* The valves in this range are fitted with adjustable bypass screws. The range is supplied with the bypass screws set for Natural gas. For LPG conversion the
bypass screws must be screwed all the way down.
Oven data
Maximum total electric load 240 V
Usable volume (cubic feet)
(including oven fans, lights, etc.)
minimum 36 1/16" (916 mm)
Left-hand Oven
2.5 kW
1.2 kW
1.15 kW
1.0 kW
Natural Gas 4" WC
Bypass
Screw*
Input
55
17,000 btu/hr
41
12,000 btu/hr
33
6,000 btu/hr
Ovens
240V (2 Wire + N + Grd), 60Hz, 7.4 kW
:
½" NPT at rear right-hand side
47 9/16" (1208 mm); see 'Positioning of Range' .
28 5/32" (723 mm)
31 ½" (800 mm)
337 LBS (153 Kg)
Right-hand Oven
2.5 kW
-
-
-
Orifice
205
150
112
46
ArtNo280-0090 Drawer Cavity & Badges
240 V 60 Hz
35 A
NEMA 14-50 P
7.4 k W, (31 A)*
maximum 37 3/16" (941mm)
Broiler
2.3 / 1.15 kW
-
-
-
Propane Gas 10" WC
Input
17,000 btu/hr
12,000 btu/hr
6,000 btu/hr
Left-hand
Right-hand
Multi-function
Convection
2.5 kW
2.77
Orifice
118
99
68
2.5 kW
2.79

Advertisement