Fitting The Cooling Fan Box; Setting The Height - AGA MERCURY AMC48DFSTB Owner's Manual

48” dual fuel range
Table of Contents

Advertisement

Fig. 12.3
Fig. 12.4
Fig. 12.5
Fig. 12.6
Fig. 12.7
INSTALLATION
Check the appliance is electrically safe when you have finished.

Fitting the cooling fan box

1.
Remove the six screws where the cooling fan box will be
fixed Fig. 12.3.
2.
The shape of the molex plug should match the socket.
Gently connect the molex plug to the molex connector
socket Fig. 12.4.
3.
The cooling fan has two tabs which connects to the
slots underneath the flue vent. Gently align the cooling
fan box tabs to the slots underneath the flue vent Fig.
12.5.
4.
Replace the six screws Fig. 12.6.
Before fitting the side panels, it is recommended
that the required height of the range is set. This will
simplify the Side Panels fitting procedure.

Setting the height

You are recommended to use a spirit level on the
hotplate to check the range is level.
The front feet and rear rollers can be adjusted to level the
range (Fig. 12.7).
1.
To adjust the height of the rear of the range, fit a 13 mm
spanner or socket wrench onto the hexagonal adjusting
nut.
2.
Rotate the nut – clockwise to raise – counter-clockwise
to lower. Make sure to lower BOTH REAR ROLLERS.
3.
To set the front turn the feet bases to raise or lower.
30