Benchmark Platinum-Edge [ii]: Operation-Service Manual
SECTION 4 – INITIAL START-UP
NATURAL GAS Manual Combustion Calibration Instructions
TABLE 4-3c: NATURAL GAS Final Valve Positions: BMK1500/2000 Duel Fuel
BMK1500 DF
Valve %
70%
6.0% ± 0.2%
50%
6.3% ± 0.2%
40%
7.0% ± 0.2%
30%
7.0% ± 0.2%
16%
8.0% ± 0.2%
TABLE 4-3d: NATURAL GAS Final Valve Positions: BMK2500 – 3000
BMK2500 Single and Duel Fuel
Single Fuel
Valve %
O
%
2
70%
5.9% ± 0.2%
50%
6.0% ± 0.2%
40%
6.3% ± 0.2%
30%
6.3% ± 0.2%
16%
6.0% ± 0.2%
BMK3000 Single and Duel Fuel
70%
5.1% ± 0.2%
50%
6.1% ± 0.2%
40%
5.0% ± 0.2%
30%
6.4% ± 0.2%
14%
6.4% ± 0.2%
TABLE 4-3e: NATURAL GAS Final Valve Positions: BMK4000
Valve Position
Single Fuel
5.5% ± 0.2%
70%
5.5% ± 0.2%
50%
5.5% ± 0.2%
40%
5.5% ± 0.2%
30%
6.0% ± 0.2%
23%
TABLE 4-3f: NATURAL GAS Final Valve Positions: 5000N
Valve Position
70%
5.5% ± 0.2%
50%
5.5% ± 0.2%
40%
5.5% ± 0.2%
30%
5.5% ± 0.2%
18%
6.0% ± 0.2%
OMM-0137_J •
12/20/2022
BMK2000 DF
O
%
2
6.5% ± 0.2%
6.5% ± 0.2%
6.5% ± 0.2%
6.5% ± 0.2%
5.5% ± 0.2%
Dual Fuel
Valve %
70%
5.9% ± 0.2%
45%
6.2% ± 0.2%
30%
6.0% ± 0.2%
20%
5.8% ± 0.2%
16%
6.0% ± 0.2%
85%
5.4% ± 0.2%
65%
5.5% ± 0.2%
45%
5.7% ± 0.2%
30%
5.6% ± 0.2%
14%
6.2% ± 0.2%
Standard NOx
O
%
NOx
2
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
Standard NO
x
O
%
NO
2
x
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST
NOx
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
NOx
O
%
2
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
≤20 ppm
Ultra-Low NOx
O
%
NOx
2
≤9 ppm
6.0% ± 0.2%
≤9 ppm
6.0% ± 0.2%
≤9 ppm
6.0% ± 0.2%
≤9 ppm
6.0% ± 0.2%
≤9 ppm
6.5% ± 0.2%
Ultra-Low NO
x
O
%
NO
2
≤9 ppm
7.5% ± 0.2%
≤9 ppm
7.5% ± 0.2%
≤9 ppm
7.5% ± 0.2%
≤9 ppm
7.5% ± 0.2%
≤9 ppm
7.5% ± 0.2%
CO
<100 ppm
<100 ppm
<50 ppm
<50 ppm
<50 ppm
CO
<100 ppm
<100 ppm
<50 ppm
<50 ppm
<50 ppm
<100 ppm
<100 ppm
<50 ppm
<50 ppm
<50 ppm
CO
<100 ppm
<100 ppm
<50 ppm
<50 ppm
<50 ppm
CO
x
<100 ppm
<100 ppm
<50 ppm
<50 ppm
<50 ppm