Object 2022H: Reset Min Max Value Pv - WIKA MH-4-CAN Special Documentation

Canopen pressure sensor
Hide thumbs Also See for MH-4-CAN:
Table of Contents

Advertisement

4. The Object Dictionary
Sub-Index
Parameter Name
Object Type
Data Type
Access
Default Value
PDO Mapping
Sub-Index
Parameter Name
Object Type
Data Type
Access
PDO Mapping
Sub-Index
Parameter Name
Object Type
Data Type
Access
PDO Mapping

4.3.6 Object 2022h: Reset Min Max Value PV

This object resets the Minimum Maximum PV Counter (see 2020h / 2021h).
The signature "zero" ('z' = 0x7A; 'e' = 0x65; 'r' = 0x72; 'o' = 0x6F) needs to be add to the
transmitted value to reset the specific PV Counter.
Index
Parameter Name
Object Type
WIKA special documentation, model MH-4-CAN
0
Number of entries
VAR
UNSIGNED8
ro
2
No
1
Maximum Value PV 1
VAR
REAL32
ro
No
2
Maximum Value PV 2
VAR
REAL32
ro
No
2022h
Reset Min Max Value PV
ARRAY
EN
67

Advertisement

Table of Contents
loading