4. The Object Dictionary
4.1.9 Object 1011h: Restore Default Parameters
This entry supports restoring of default parameters.
With a read access the transmitter provides information about its capabilities to restore
these values.
Sub-index 1: All parameters
■
Sub-index 2: Communication Parameters
■
Sub-index 3: Application parameters
■
For restoring the signature "load" (0x64616f6c) must be written.
Index
Parameter Name
Object Type
Sub-Index
Parameter Name
Object Type
Data Type
Lower Limit
Higher Limit
Access
Default Value
PDO Mapping
Sub-Index
Parameter Name
Object Type
Data Type
Access
PDO Mapping
WIKA special documentation, model MH-4-CAN
1011h
Restore Default Parameters
ARRAY
0
Number of entries
VAR
UNSIGNED8
0x0
0x7F
ro
4
No
1
Restore all Default Parameters
VAR
UNSIGNED32
rw
No
EN
23