VERSION 12/2018
7.2.3 REPLACING THE AIRLESS FLAT JET NOZZLE
1. Thoroughly flush the spray gun with cleaning agent.
2. Relieve the pressure of the spray gun and device!
3. Secure the spray gun (pull out control air hose).
4. Unscrew union nut (E).
5. Remove flat jet nozzle (D).
Note:
Pay attention to seal (C).
Assembly:
6. Insert cleaned or new flat jet nozzle (D) in union nut (E).
7. Insert seal (C) in union nut.
8. Place union nut with nozzle and seal on spray gun and slightly tighten.
9. Turn the flat jet nozzle (D) so that it corresponds to the desired spray pattern.
10. Tighten union nut (E).
11. Connect control air hose (A) again.
B
C
D
E
B_00864
7.2.4 CLEANING THE AIRLESS FLAT JET NOZZLE
The Airless flat jet nozzle (D) can be placed in a cleaning solution recommended by the lacquer
manufacturer.
Attention:
Sharp-edged objects cannot be used on the flat jet nozzle.
ORDER NUMBER DOC 350941
A
GA 250AL_GA 400AL
29