Preparing the spray gun
2.3
Connecting the spray gun
Before you commence connecting the gun, switch off the powder feed. For information on this
activity refer to the related operating instructions for the control units and control modules.
Hint
Use the parts listed in chapter
gun.
The spacing between the spray guns when fitted must be at least 300 mm.
•
Mount the spray gun via cross attaching piece K for example on the gun holder of the
reciprocator. If an oscillator is being used, the spray gun must be fixed with a clamping
element (see accessories).
•
Connect the spray gun to the Tribo current measuring or display module using the
electrical cable.
•
Connect the hoses for the powder feed and also Tribo and atomizing air to the spray gun.
Hint
By using a Wagner PI-F1 powder injector and a suitable control unit, it is
possible to blow out or flush the spray gun automatically each time before it is switched
off.
05 / 2009
9
"Accessories" for connecting and fastening the spray
Electrical connection
from the control unit
Atomizing air
P_00743
0351701
E
A
G
The spray gun must be
K
grounded via the
grounding screw G!
- PEA-T3XL
Powder feed
P
from the
powder injector
T
Tribo air
Attention
11