8
SET MODE
Connectors
» SET > Connectors
MIC Jack 8V Output
Selects whether or not to output 8 V from the [MIC]
jack.
• OFF: Output 3.3 V from the [MIC] jack.
• ON: Output 8 V from the [MIC] jack.
REF OUT
Sets the timing of the reference frequency signal
output from the [REF OUT 10 MHz/-10 dBm]
connector on the RF unit.
• Auto (CX-10G:ON): Automatically outputs the
reference signal only when the
optional CX-10G is connected.
• ON:
Outputs the reference signal
anytime.
(Default: OFF)
(Default: Auto (CX-10G:ON))
Network
» SET > Network
DHCP (Valid after Restart)
Turns the DHCP function ON or OFF.
• OFF: Uses a static IP address.
• ON: Uses the DHCP function. If a DHCP server is
in your network environment, the IP address
is automatically obtained.
IP Address (Valid after Restart)
Sets the static IP address.
L You cannot set the same address as "Default Gateway."
Subnet Mask (Valid after Restart)
Sets the subnet mask to connect to your PC or Local
Area Network (LAN), through your Router.
Default Gateway (Valid after Restart)
Sets the Default Gateway of the IC-905.
When you remotely control the IC-905 or use the
Internal Gateway function, a Default Gateway setting
is required.
Primary DNS Server (Valid after Restart)
Sets the Primary DNS Server address.
2nd DNS Server (Valid after Restart)
If there are two DNS server addresses, sets the
secondary DNS server address.
Network Name
If you are operating the IC-905 using the optional
RS-BA1 or transferring a picture to the IC-905 using
the optional ST-4001W, enter a network name of up to
15 characters.
» SET > Network > Remote Settings
Network Control (Valid after Restart)
Selects whether or not to remotely control the IC-905.
• OFF: Disables remote control of the IC-905.
• ON: Enables remote control of the IC-905.
8-16
(Default: ON)
(Default: 192.168.0.10)
(Default: 255.255.255.0(24 bit))
(Default: . . . .)
(Default: . . . .)
(Default: . . . .)
(Default: OFF)
Need help?
Do you have a question about the IC-905 and is the answer not in the manual?