C o n f i g u r i n g t h e M D r i v e S p e e d C o n t r o l f o r
B i d i r e c t i o n a l O p e r a t i o n
When setting the MDrive Speed Control for bidirectional operation, it is
necessary that the joystick or pot be calibrated. First, a center position must
be established, as well as the full scale range of the input device in two
directions. The following steps outline the calibration procedures.
1] With the input device in the center position, click
"Analog>Initialize" on the menu bar.
2] Move the input device to its full scale position, first in the max
direction, then in the min direction. Re-center the input device.
3] Click the "Accept" button.
4] Set the other parameters to the desired value.
5] Click the "Set" button to save the parameter settings to non-
volatile memory.
then click "Accept"
Figure 1.7.6: Accepting the Analog Initialization Values
Figure 1.7.5: Initialization Mode
Counts (Volts or mA) will change...
Click Analog and Initialize
Clicking on the label will change
the units from Cts (Counts) to
V (Volts) to mA (milliAmps)