Interfacing Power And Speed Control Inputs (Connector P1); Interfacing The Mdrive Speed Control - IMS MDRIVE 17 Operating Instructions Manual

Hide thumbs Also See for MDRIVE 17:
Table of Contents

Advertisement

S e c t i o n 1 . 5
I n t e r f a c i n g T h e M D r i v e S p e e d C o n t r o l
S e c t i o n O v e r v i e w
This section covers the hardware interface of the MDrive versions with
integrated speed control electronics. Refer to Section 1.6 for Parameter setup
and configuration. Covered in the section are:
L a y o u t a n d I n t e r f a c e G u i d e l i n e s
Logic level cables must not run parallel to power cables. Power cables will
introduce noise into the logic level cables and make your system unreliable.
Logic level cables must be shielded to reduce the chance of EMI induced noise.
The shield needs to be grounded at the signal source to AC ground. The other
end of the shield must not be tied to anything, but allowed to float. This
allows the shield to act as a drain.
Power supply leads to the driver need to be twisted. If more than one MDrive
is to be connected to the same power supply, run separate power and ground
leads from the supply to each MDrive.
R e c o m m e n d e d W i r i n g
The following wiring/cabling is recommended for use with the MDrive:
Recommended Wire Size
Logic Wiring ............................................................................... 22 AWG
Power and Ground .................... See Appendix A "Recommended Cable
G e n e r a l P r a c t i c e s
The following wire strip length is recommended:
Wire Strip Length ........................................................... 0.250" (6.0 mm)
NOTE: Wire and insulation type are subject to the user's application and environment.
Layout and Interface Guidelines

Interfacing Power and Speed Control Inputs (Connector P1)

Interfacing the SPI Interface (Connector P2)
WARNING! DO NOT connect or disconnect power leads when
power is applied! Disconnect the AC power side to power down
the DC power supply. For battery operated systems, connect a
"transient suppressor" across the power switch to prevent arcs
and high voltage spikes.
WARNING! See Part II for power supply requirements for the
MDrive17, Part III for the MDrive23.