Failure to restrain the
fryer could allow it to
move or tip, causing hot oil to splash or
spill out, or a possible break in the gas
line causing an explosive condition. The
means of restraint may be the manner of
installation, such as connection to a
battery of appliances or installing the
fryer in an alcove, or by separate means,
such as adequate ties.
The installation must
conform with local codes,
or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1, as
applicable, including;
i) The appliance and its individual shutoff
valve must be disconnected from the gas
supply piping system during any
pressure testing of that system at test
pressures in excess of 1/2 psi (3.5 kPa).
ii) The appliance must be isolated from
the gas supply piping system by closing
its individual manual shutoff valve during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
The appliance, when
installed, must be
electrically grounded in accordance with
local codes, or in the absence of local
codes, with the National Electrical Code,
NFPA 70, or the Canadian Electrical
Code, CSA C22.2, as applicable.
W-2
broaster.com Manual #20932 5/19 Rev: 05/19