ALERT SETTINGS:
Pressing this option allows you to set con-
ditions for several features.
The numbers left of the boxes indicate the
current setting. They can be changed by
pressing the "-" or "+" buttons.
Filter Reminder Cycles: This sets the num-
ber of cook cycles between each oil filter
cycle. The Broaster Company recommends
5 cook cycles however, you can set it as
you desire. A setting of "0" will disable the
filter reminder screen.
Alert Volume: This should be set loud
enough to be able to hear it above any
other noises in the kitchen.
Keypad Volume: It should be loud enough
to hear while making changes in front of the
fryer or when operating the fryer.
Tone: There are a range of tones from low
to very high. Chose the one that suits your
operation.
Stir/Agitate Reminder: This alert appears
when 3 conditions occur.
1. When the fryer is first turned on in the
morning, this reminder will appear after the
oil comes up to the set temperature.
2. After a filter cycle has been completed
6-12
broaster.com Manual #20932 05/19 Rev: 05/19
this reminder will appear after the oil comes
up to the set temperature.
3. If the fryers has been setting idle for 2
hours or longer this reminder will appear to
alert you to stir the oil to get it to a uniform
temperature.
Pressure Release at end of Cycle: This
setting allows the pressure to release
before the cooking time reaches zero.
Drain Plugged Warning: This controls
whether the unit warns the operator that the
drain may be clogged.
Incomplete Evac. Warning: This controls
whether the unit warns the operator that the
oil may not have fully returned to the cook-
ing well after the auto-filter evacuation time
has expired.
After making the adjustments on this dis-
play press the green OK button to save the
entries.
To go back to the Cook display either press