SOLID STATE CONTROLLER TIPS

COMPLAINT
Display reads FAIL
Display reads HI
Display reads PROB
Display reads CHEC

FROZEN IQF PRODUCT

COMPLAINT
Product too light
Product too dark
Product not done
No flavor
White spots
Dark spots
CAUSE
1. There is a controller fail-
ure
1. Oil temperature too high
1. There is a temperature
sensor probe failure
1. Oil temperature not rising
properly
CAUSE
1. Low oil temperature
2. Not done
3. Food basket overloaded
1. High oil temperature
2. Overcooked
3. Oil old
4. Thawed and refrozen
1. Low oil temperature
2. Food basket overloaded
3. Cook time too short
1. Overcooked
2. Old product
1. Product stuck together
2. Food basket overloaded
1. Dirty oil
6-3
broaster.com Manual #16501 7/06 Rev 2/15
REMEDY
1. Push power OFF button
1. Push power OFF button
1. Push power OFF button
1a. Check wall fuse or circuit
breaker
1b. Push power OFF button
REMEDY
1. Check cook temperature
2. Increase cook time
3. Decrease load
1. Check cook temperature
2. Decrease cook time
3. Change oil
4. Keep product at 0° F or
below
1. Check cook temperature
2. Decrease load
3. Increase cook time
1. Check cook time
2. Discard
1. Distribute product evenly
in basket while loading
2. Decrease load size
1. Filter or replace