Hi Limit Control - Broaster VF-2 Service & Parts Manual

Ventless fryer
Table of Contents

Advertisement

HI-LIMIT CONTROL
ACCESS FOR SERVICE
1. Remove Access Panel Retaining
Screw (25). Raise the Access Panel
(26) and pull it outward.
HI-LIMIT CONTROL DIAGNOSTICS
There are 3 conditions which could cause
the Hi-Limit control to trip.
CONDITION 1:
25
If the alarm light on the Hi-Limit Control is
illuminated, push the Reset button to reset
26
the control once the oil has cooled. If push-
ing the Reset button does not reset the
control and turn the alarm light off, either
condition 2 or 3 exists.
CONDITION 2: Probe Failure
4-4
broaster.com Manual #16501 7/06 Rev 2/15
Condition 1: The oil temperature has
risen above 450° F (416° F on CE units).
Condition 2: The probe has failed or a
loose connection.
Condition 3: The control has failed or
lost power.
1. See ACCESS FOR SERVICE
Push Reset button
to reset control
If alarm light is lit, the control
has tripped.
1. Disconnect power from the unit.
2. Disconnect probe wires from terminals 6
& 7 and connect a new probe. Yellow
to + and Red to -.