VF2 Grease Filter Switch:
C2 Contactor
30
The Grease Filter Switch (30) is mounted to
the interior wall in front of the C2 Contactor.
1. See Access For Service.
2. Disconnect both wire leads (31).
3. Check across wire leads (31). Meter
should indicate a closed circuit. If not,
switch is faulty.
4. Unlatch filter cartridge (32) and pull out
as shown. Check across wire leads
(31). Meter should indicate an open
circuit. If not, switch is faulty.
31
32
broaster.com Manual #16501 7/06 rev 2/15
VF2 Grease Filter Switch Replacement:
1. See Access For Service.
2. Loosen hex nut and slide switch out of
bracket.
3. Disconnect switch lead wires (31) if not
already disconnected.
4. Reassemble in reverse order making
sure end of switch is against the inte-
rior panel and slid fully into bracket.
VF2 Pressure Switch:
34
Pressure Switch (34) is mounted on two
studs on the interior wall and held in place
by two nuts.
1. See Access For Service.
2. With a needle nose pliers, disconnect
bot wires form the terminals.
3. Remove Filter Cartridge (32) from unit.
4. Remove nuts holding pressure switch
in place.
5. Carefully remove tubing (35) con-
nected to switch.
6. Reassemble in reverse order.