Broaster VF-2 Service & Parts Manual page 66

Ventless fryer
Table of Contents

Advertisement

VF3i Grease Filter Switch Replacement:
1. See Access For Service.
2. Disconnect lead wires (45) and clip off
the terminals on the lead wires.
3. Unlatch and remove Filter Tray (32).
4. Remove boot (44) and loosen nut (46).
46
5. Pull switch and leads out of mounting
fitting (47).
6. Thread lead wires of new switch
through nut (46) and fitting (47).
7. Tighten nut (46) finger tight then 1/4
turn more. DO NOT TIGHTEN NUT
MORE THEN 1/4 TURN PAST FIN-
GER TIGHT.
8. Push boot (44) over fitting (47) until the
end is touching the side wall as shown
below.
47
broaster.com Manual #16501 7/06 rev 2/15
9. Install terminal shown below on each
wire lead.
10. Plug terminals into receptacles (45).
11. Check across wire lead. Meter should
indicate a closed circuit. If not switch
is faulty.
12. Reinstall Filter Tray (32).
13. Check across wire leads (45). Meter
should indicate an open circuit. If not,
switch is faulty.
14. If test results are ok, plug lead wire
into receptacles that they were
removed from. See below.
45
Unit is now ready to operate.