Diagnostics
Code
Description
20
Hi Temperature
20
Hi Limit Trip
20
Heater Fault
20
Open Probe
Airflow Error
20
Hours shown after last
Inspection alarm reset
Current hours: 337
Serial Number: 123456789
Install Date: 09/29/2020
Firmware Version 0.09
BROASTER COMPANY ● BELOIT, WI USA
PARTS AND SERVICE SUPPLIED BY AUTHORIZED BROASTER DISTRIBUTORS
ERROR CODE DIAGNOSTICS
This screen provides a history of any error
messages that were generated. The control
displays the current hours so an approxi-
mate time of occurrence may be deter-
mined. The hours counter is reset to zero
after the semi-annual fire system inspection
has been performed.
Hours
313
312
309
309
300
OK
POWER
broaster.com Manual #16501 8/06 Rev 10/20
SERVICING THE SMARTTOUCH
DISPLAY
The display PCB may be replaced by
removing the wire terminations and
unscrewing the 6 keps nuts that attached it
to the chassis. Order the following item:
18107 CONTROL, TOUCHSCREEN, VF
If the touchscreen needs to be replaced,
order one of the following items.
K18108 ASM, CHASSIS, W/ OVERLAY,
VF2
K18109 ASM, CHASSIS, W/ OVERLAY,
VF3