Broaster VF-2 Service & Parts Manual page 41

Ventless fryer
Table of Contents

Advertisement

Diagnostics
Code
Description
20
Hi Temperature
20
Hi Limit Trip
20
Heater Fault
20
Open Probe
Airflow Error
20
Hours shown after last
Inspection alarm reset
Current hours: 337
Serial Number: 123456789
Install Date: 09/29/2020
Firmware Version 0.09
BROASTER COMPANY ● BELOIT, WI USA
PARTS AND SERVICE SUPPLIED BY AUTHORIZED BROASTER DISTRIBUTORS
ERROR CODE DIAGNOSTICS
This screen provides a history of any error
messages that were generated. The control
displays the current hours so an approxi-
mate time of occurrence may be deter-
mined. The hours counter is reset to zero
after the semi-annual fire system inspection
has been performed.
Hours
313
312
309
309
300
OK
POWER
broaster.com Manual #16501 8/06 Rev 10/20
SERVICING THE SMARTTOUCH
DISPLAY
The display PCB may be replaced by
removing the wire terminations and
unscrewing the 6 keps nuts that attached it
to the chassis. Order the following item:
18107 CONTROL, TOUCHSCREEN, VF
If the touchscreen needs to be replaced,
order one of the following items.
K18108 ASM, CHASSIS, W/ OVERLAY,
VF2
K18109 ASM, CHASSIS, W/ OVERLAY,
VF3
2-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf3i

Table of Contents