Change Cook Temperature:
Action: Press the TEMP button once.
Response: The TIME display will turn
off and the TEMP display will be flash-
ing.
Action: Key in the desired temperature
setting then press the TEMP button to
save the new setting.
If a button is not pressed
in ten seconds, the dis-
play will revert back to both the TIME
and TEMP displays flashing.
Advance to Next Preset:
Action: Press the CYCLE COUNT
RESET button once.
Response: The CYCLE COUNT dis-
play will change to "-1" and the pre-
sets for #1 will be displayed.
Repeat the process as described. After the
presets for #9 are displayed, pressing the
RESET button again will cause the control
to return to normal operation.
Even if all presets are not
programed the reset but-
ton must be pressed until "-9" appears
then press reset button once more to
hold programs.

WARNING DISPLAYS

HI - Display will flash HI if cooking oil tem-
perature exceeds 415
sound until power switch is turned OFF or
hi-limit trips. All controller functions and
heat source are disabled during this condi-
tion.
PROB - Display will flash PROB if there is a
problem with temperature sensor probe.
Audible alert will sound until power switch
is turned OFF. All controller functions and
heat source are disabled during this condi-
tion.
CHEC - Display will flash CHEC if cooking
oil temperature does not rise 6
first three minutes. Audible alert will sound
until power switch is turned OFF. All con-
troller functions and heat source are dis-
abled during this condition.
Note: CHEC could appear if cooking oil
temperature is below 45
switch OFF then ON for another three min-
ute heating period. This may have to be
repeated two or three times.
FAIL - Display will flash FAIL if controller
detects a fault within itself. Audible alert
will sound until power switch is turned OFF.
All controller functions and heat source are
disabled during this condition.
2-4
broaster.com Manual #16501 8/06 Rev 10/20
°
F. Audible alert will
°
F within the
°
F. Turn power