Broaster VF-2 Service & Parts Manual page 61

Ventless fryer
Table of Contents

Advertisement

2. Disconnect wires from switch (33).
Check across terminals. Meter should
indicate an open circuit. If not, switch
is faulty.
3. Unlatch filter cartridge (32) and pull out
as shown. Check across terminals.
Meter should indicate a closed circuit.
If not, switch is faulty.
Air Filter Switch Replacement.
1. Disconnect main power supply.
2. T access for service remove the top
cover.
33
32
Spring
Retaining
Clip (2)
broaster.com Manual #16501 7/06 rev 2/15
3. Disconnect wires from Air Filter Swtich
(33).
4. Depress the two spring retaining clips
on the switch and push switch into the
cooking compartment.
5. Reassemble in reverse order.
VF2 Access Door Switch:
The Access Door Switch (21) is located in
the upper area where the fan is mounted. To
access it remove the top cover.
1. Disconnect both switch wire leads
(22).
2. With Access Door open, check across
wire leads (22). Meter should indicate
an open circuit. If not, switch is faulty.
3. With Access Door closed and latched
check across wire leads (22). Meter
should indicate a closed circuit. If not,
switch is faulty.
5-6
21
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vf3i

Table of Contents