6. Install new probe in the same location
as old probe. End of probe sheath
should be 1/8" above nut (30) when
installed properly.
7. Tighten nut (30).
8. Carefully thread wires through Element
Shaft.
9. Reassemble Element Shaft by revers-
ing the ELEMENT SHAFT REMOVAL
instructions.
10. Reconnect power to unit.
HI-LIMIT EFFECTIVE SERIAL NUM-
BERS VF3J02112 and VF2_02003G
The hi-limit has a set point of 415F. If the hi-
limit trips, the temperature must be brought
below 375F and power must be removed
from the device by unplugging the appliance
for it to reset.The part number is 18025
CONTROL- HI LIMIT, 415F,120VAC.
HEAT ELEMENT
4-6
broaster.com Manual #16501 7/06 Rev 2/15
1. See Temperature Sensor Probe
2. Disconnect Heater wires (31).
31
3. Remove screws (32) and remove Heat-
ing Element from Connector box (18).
32
4. Reassemble in reverse order.
31
18