Figure 96. C7-3: 24 x 2.5-inch SAS4/SATA w/ 8 x Uni (w/ FPERC11)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 94. 24 x 2.5-inch SAS4/SATA w/ 8 x Uni (w/ FPERC11)
Order
1
2
3
4
5
6
7
8
9
From
SL1_CPU2_PA4 (signal connector on system
board)
SL2_CPU2_PB4 (signal connector on system
board)
SIG_PWR_1 (system board power connector)
SL3_CPU1_PA1 (signal connector on system
board)
CTRL_SRC_SB1 (fPERC controller connector)
CTRL_SRC_SA1 (fPERC controller connector)
SL4_CPU1_PB1 (signal connector on system
board)
SL5_CPU1_PB2 (signal connector on system
board)
SIG_PWR_2 (system board power connector)
To
DST_PA1 (backplane signal connector)
DST_PB1 (backplane signal connector)
BP_PWR_1 (backplane power connector)
CTRL_DST_PA1 (fPERC input connector)
BP_DST_SB1 (backplane expander signal
connector)
BP_DST_SA1 (backplane expander signal
connector)
DST_PA2 (backplane signal connector)
DST_PB2 (backplane signal connector)
BP_PWR_2 (backplane power connector)