Dell PowerEdge R7625 Installation And Service Manual page 120

Table of Contents

Advertisement

Figure 87. C3-3: 8 x U.2 G4 RAID (w/ FPERC12)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 85. 8 x U.2 G4 RAID (w/ FPERC12)
Order
1
2
3
4
5
120
Installing and removing system components
From
SL1_CPU2_PA4 (signal connector on system
board)
SL2_CPU2_PB4 (signal connector on system
board)
SIG_PWR_1 (system board power connector)
CTRL_SRC_PB1 (fPERC controller connector)
CTRL_SRC_PA1 (fPERC controller connector)
To
CTRL_DST_PA1 (fPERC input
connector)
CTRL_DST_PB1 (fPERC input
connector)
BP_PWR_1 (backplane power
connector)
DST_PA2 (backplane signal connector)
and DST_PB2 (backplane signal
connector)
DST_PA1 (backplane signal connector)
and DST_PB1 (backplane signal
connector)

Advertisement

Table of Contents
loading

This manual is also suitable for:

E94sE94s001

Table of Contents