Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
York Manuals
Chiller
YVAA
Installation operation & maintenance
Table 29 - R-134A Pressure To Saturated Temperature Conversion - York YVAA Installation Operation & Maintenance
Air-cooled screw liquid chillers, air-cooled screw liquid chillers with variable speed drive
Hide thumbs
Also See for YVAA
:
Installation, operation & maintenance instructions manual
(178 pages)
,
Service information
(3 pages)
1
2
3
4
5
Table Of Contents
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
page
of
192
Go
/
192
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Form 201.47-ICOM1
Issue date: 17/11/2022
Table 29 - R-134a pressure to saturated temperature conversion
Pressure
Dew point tem-
psig (bar)
perature
0.0 (0.0)
-14.9 (-26.1)
5.0 (0.34)
-3.0 (-19.4)
10.0 (0.69)
6.7 (-14.1)
15.0 (1.03)
14.9 (-9.5)
20.0 (1.38)
22.2 (-5.4)
25.0 (1.72)
28.7 (-1.8)
30.0 (2.07)
34.6 (1.4)
35.0 (2.41)
40.0 (4.4)
40.0 (2.76)
45.0 (7.2)
45.0 (3.10)
49.6 (9.8)
50.0 (3.45)
54.0 (12.2)
55.0 (3.79)
58.1 (14.5)
60.0 (4.14)
62.0 (16.7)
65.0 (4.48)
65.7 (18.7)
70.0 (4.83)
69.2 (20.7)
75.0 (5.17)
72.6 (22.6)
80.0 (5.52)
75.9 (24.4)
85.0 (5.86)
79.0 (26.1)
90.0 (6.21)
82.0 (27.8)
95.0 (6.55)
84.9 (29.4)
100.0 (6.89)
87.7 (30.9)
105.0 (7.24)
90.4 (32.4)
110.0 (7.58)
93.0 (33.9)
115.0 (7.93)
95.5 (35.3)
120.0 (8.27)
98.0 (36.7)
125.0 (8.62)
100.4 (38.0)
130.0 (8.96)
102.7 (39.3)
JOHNSON CONTROLS
Pressure
F (
C)
psig (bar)
0
0
135.0 (9.31)
140.0 (9.65)
145.0 (10.0)
150.0 (10.34)
155.0 (10.69)
160.0 (11.03)
165.0 (11.38)
170.0 (11.72)
175.0 (12.07)
180.0 (12.41)
185.0 (12.76)
190.0 (13.10)
195.0 (13.44)
200.0 (13.79)
205.0 (14.13)
210.0 (14.48)
215.0 (14.82)
220.0 (15.17)
225.0 (15.51)
230.0 (15.86)
235.0 (16.20)
240.0 (16.55)
245.0 (16.89)
250.0 (17.24)
255.0 (17.58)
260.0 (17.93)
265.0 (18.27)
Dew point tem-
Pressure
perature
F (
C)
psig (bar)
0
0
105.0 (40.6)
270.0 (18.62)
107.2 (41.8)
275.0 (18.96)
109.4 (43.0)
280.0 (19.31)
111.5 (44.2)
285.0 (19.65)
113.6 (45.3)
290.0 (19.99)
115.6 (46.4)
295.0 (20.34)
117.6 (47.6)
300.0 (20.68)
119.6 (48.7)
305.0 (21.03)
121.5 (49.7)
310.0 (21.37)
123.3 (50.7)
315.0 (21.72)
125.2 (51.8)
320.0 (22.06)
126.9 (52.7)
325.0 (22.41)
128.7 (53.7)
330.0 (22.75)
130.4 (54.7)
335.0 (23.10)
132.1 (55.6)
340.0 (23.44)
133.8 (56.6)
345.0 (23.79)
135.5 (57.5)
350.0 (24.13)
137.1 (58.4)
355.0 (24.48)
138.7 (59.3)
360.0 (24.82)
140.2 (60.1)
365.0 (25.17)
141.8 (61.0)
370.0 (25.51)
143.3 (61.8)
375.0 (25.86)
144.8 (62.3)
380.0 (26.20)
146.3 (63.5)
385.0 (26.54)
147.7 (64.3)
390.0 (26.89)
149.2 (65.1)
395.0 (27.23)
150.6 (65.9)
400.0 (27.58)
SECTION 9 - MAINTENANCE
Dew point tem-
perature
F (
C)
0
0
152.0 (66.7)
153.4 (67.4)
154.7 (68.2)
156.1 (68.9)
157.4 (69.7)
158.7 (70.4)
160.0 (71.1)
161.3 (71.8)
162.5 (72.5)
163.8 (73.2)
165.0 (73.9)
166.2 (74.6)
167.4 (75.2)
168.6 (75.9)
169.8 (76.6)
171.0 (77.2)
172.1 (77.8)
173.3 (78.5)
174.4 (79.1)
175.5 (79.7)
176.6 (80.3)
177.7 (80.9)
178.8 (81.6)
179.9 (82.2)
180.9 (82.7)
182.0 (83.3)
183.0 (83.9)
169
9
Table of
Contents
Previous
Page
Next
Page
1
...
168
169
170
171
Show Quick Links
Quick Links:
Figure 1 - Yvaa Air-Cooled Screw...
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for York YVAA
Chiller York YVAA Installation, Operation & Maintenance Instructions Manual
Air-cooled screw liquid chillers with variable speed drive (178 pages)
Chiller York YVAA Service Information
(3 pages)
Chiller York YVWA Manual
Water-cooled variable speed screw chiller (4 pages)
Chiller York YVWA Installation Operation & Maintenance
Water-cooled screw liquid chillers, single compressor 50 hz and 60 hz, 125 - 200 ton, 440 - 700 kw (156 pages)
Chiller York YVAA Style A Installation Operation & Maintenance
Air-cooled screw liquid chiller (184 pages)
Chiller York YVAM Start-Up Checklist
(6 pages)
Chiller York YVAM Installation Procedure
Air-cooled centrifugal liquid chiller (54 pages)
Chiller York YCAL0065 User Manual
Air-cooled scroll chillers style d 50 and 60hz 47 – 60 ton 165 – 210 kw (80 pages)
Chiller York YCAL0080SC Installation Operation & Maintenance
Millennium series air-cooled liquid chillers hermetic scroll (136 pages)
Chiller York Millennium YK M3 M3 G4 THRU YK S6 S4 J2, YK LB LB G4 THRU YK SE SC J4 Operating & Maintenance Manual
Centrifugal liquid chillers with microcomputer control center (61 pages)
Chiller York YCAL0019 Installation Operation & Maintenance
Air-cooled scroll chillers (200 pages)
Chiller York YLUA Series Operation Manual
Air-cooled scroll compressor condensing units (52 pages)
Chiller York MILLENNIUM YCAS0250 Wiring Diagram
Air cooled screw liquid chillers style f (34 pages)
Chiller York YK Series Installation Manual
Chillers (style h) field reassembly for form 3, 7, 9, and 10 shipment (34 pages)
Chiller York YZ Wiring Diagrams
(20 pages)
Chiller York YZ Engineering Manual
Magnetic bearing centrifugal chiller (24 pages)
Related Content for York YVAA
YCIV0157 Table 55 - R-134A Pressure To Saturated Temperature Conversion
York YCIV0157
YVAA Style A Table 28 - R-134A Pressure To Saturated Temperature Conversion
York YVAA Style A
YCIV Series Table 34 - R-134A Pressure To Saturated Temperature Conversion
York YCIV Series
YCAV1039 Table 29 - R-134A Pressure To Saturated
York YCAV1039
Millennium YCAS 316 Temperature Conversion Table
York Millennium YCAS 316
YCAV0267E Table 29 - R-134A Pressure To Saturated
York YCAV0267E
YR TB TB T0 Pressure/Temperature Conversion Tables
York YR TB TB T0
YVAA Table 28 - R-513A Refrigerant Pressure To Saturated Temperature
York YVAA
MAXE YK Pressure - Temperature Chart
York MAXE YK
YLAA0041 Table 37: Temperature Conversion Chart
York YLAA0041
YCAV0157 R-134A Conversion Tables
York YCAV0157
YCAS Temperature Conversion Chart
York YCAS
MILLENNIUM YCAS 250 Temperature Conversion Chart
York MILLENNIUM YCAS 250
YCAE065 R410A Pressure Temperature Chart
York YCAE065
YCAS0373SC Temperature Conversion Chart
York YCAS0373SC
YCAV0569 R-134A Conversion Tables
York YCAV0569
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL