York YVAA Installation Operation & Maintenance page 76

Air-cooled screw liquid chillers, air-cooled screw liquid chillers with variable speed drive
Table of Contents

Advertisement

SECTION 5 - TECHNICAL DATA
Table 9 - Optional three-pass inlet/outlet connections (cont'd)
YVAA
A
Model
1603.6
0199/0699
915.0 (36.02)
(63.13)
1603.6
0234/0824
915.0 (36.02)
(63.13)
1583.6
0261/0921
895.0 (35.24)
(62.35)
1034.4
0216/0756
(40.72)
1603.6
0226/0796
(63.13)
1603.6
0259/0919
(63.13)
1583.6
0266/0936
(62.35)
1034.4
0219/0769
(40.72)
1603.6
0229/0809
(63.13)
1603.6
0264/0924
(63.13)
1603.6
0246/0866
(63.13)
1583.6
0269/0949
(62.35)
1583.6
0324/1134
(62.35)
1583.6
0294/1034
(62.35)
1583.6
0331/1161
(62.35)
1583.6
0306/1076
(62.35)
1583.6
0309/1089
(62.35)
1583.6
0334/1174
(62.35)
1501.5
0491/1731
(59.11)
1501.5
0361/1271
(59.11)
1501.5
0391/1381
(59.11)
1501.5
0456/1606
(59.11)
1501.5
0399/1409
(59.11)
1501.5
0469/1649
(59.11)
1501.5
0459/1549
(59.11)
Note: The minimum and maximum flow rates listed here only represent the span of flows for a group of available evaporator options. Actual
chiller flow rates vary based on specific evaporator configurations. The application datasheet or nameplate must be referenced for specific flow
limits for every chiller.
Note: Minimum Chilled Water Flow Rate is for full load selections; Variable Primary Flow ratings as low as 50% of the minimum are
permitted. Glycol limits are higher. Contact your Johnson Controls Sales Office for ratings and further information.
76
All dimensions - in. (mm)
B
C1
C2
1073.3
1117.6 (44.00)
(42.26)
1073.3
1117.6 (44.00)
(42.26)
1117.6
1117.6 (44.00)
(44.00)
3696.8
1077.3
1117.6 (44.00)
(145.54)
(42.41)
2032.0
1073.3
1117.6 (44.00)
(80.00)
(42.26)
2032.0
1073.3
1117.6 (44.00)
(80.00)
(42.26)
2012.0
1117.6
1117.6 (44.00)
(79.21)
(44.00)
4813.8
1077.3
1117.6 (44.00)
(189.52)
(42.41)
3149.0
1073.3
1117.6 (44.00)
(123.98)
(42.26)
3149.0
1073.3
1117.6 (44.00)
(123.98)
(42.26)
3149.0
1073.3
1117.6 (44.00)
(123.98)
(42.26)
3129.0
1117.6
1117.6 (44.00)
(123.19)
(44.00)
3129.0
1117.6
1117.6 (44.00)
(123.19)
(44.00)
3129.0
1117.6
1117.6 (44.00)
(123.19)
(44.00)
4245.0
1117.6
1117.6 (44.00)
(167.13)
(44.00)
4245.0
1117.6
1117.6 (44.00)
(167.13)
(44.00)
5363.0
1117.6
1117.6 (44.00)
(211.14)
(44.00)
5363.0
1117.6
1117.6 (44.00)
(211.14)
(44.00)
4198.9
917.6
1317.6
(165.31)
(36.13)
(51.87)
4163.9
917.6
1317.6
(163.93)
(36.13)
(51.87)
4198.9
917.6
1317.6
(165.31)
(36.13)
(51.87)
6403.9
917.6
1317.6
(252.12)
(36.13)
(51.87)
6438.9
917.6
1317.6
(253.50)
(36.13)
(51.87)
7520.9
917.6
1317.6
(296.10)
(36.13)
(51.87)
4198.9
917.6
1317.6
(165.31)
(36.13)
(51.87)
E-nozzle
D
D2
size
366.7
666.1 (26.22)
5
(14.44)
366.7
666.1 (26.22)
5
(14.44)
373.0
703.0 (27.68)
5
(14.69)
353.1
678.1 (26.70)
5
(13.90)
366.7
666.1 (26.22)
5
(14.44)
366.7
666.1 (26.22)
5
(14.44)
372.9
703.0 (27.68)
6
(14.68)
353.1
678.1 (26.70)
4
(13.90)
366.7
666.1 (26.22)
5
(14.44)
366.7
666.1 (26.22)
5
(14.44)
366.7
666.1 (26.22)
5
(14.44)
372.9
703.0 (27.68)
6
(14.68)
372.9
703.0 (27.68)
6
(14.68)
372.9
703.0 (27.68)
6
(14.68)
372.9
703.0 (27.68)
6
(14.68)
372.9
703.0 (27.68)
6
(14.68)
372.9
703.0 (27.68)
6
(14.68)
372.9
703.0 (27.68)
6
(14.68)
393.7
783.7 (30.85)
6
(15.50)
393.7
703.0 (27.68)
6
(15.50)
393.7
703.0 (27.68)
6
(15.50)
393.7
783.7 (30.85)
6
(15.50)
393.7
703.0 (27.68)
6
(15.50)
393.7
783.7 (30.85)
6
(15.50)
393.7
783.7 (30.85)
6
(15.50)
Form 201.47-ICOM1
Issue date: 17/11/2022
Minimum
Water
chilled water
Figure
volume gal
flow rate
(l)
GPM (l/s)
A
31 (120)
130 (8.2)
A
44 (170)
130 (8.2)
A
44 (170)
220 (14)
A
31 (120)
130 (8.2)
A
44 (170)
130 (8.2)
A
44 (170)
130 (8.2)
A
52 (200)
220 (14)
A
31 (120)
130 (8.2)
A
44 (170)
130 (8.2)
A
44 (170)
130 (8.2)
A
52 (200)
130 (8.2)
A
52 (200)
220 (14)
A
52 (200)
220 (14)
A
52 (200)
220 (14)
A
52 (200)
220 (14)
A
52 (200)
220 (14)
A
52 (200)
220 (14)
A
52 (200)
220 (14)
B
52 (200)
270 (17)
B
52 (200)
270 (17)
B
52 (200)
270 (17)
B
52 (200)
270 (17)
B
52 (200)
270 (17)
B
52 (200)
270 (17)
B
52 (200)
270 (17)
JOHNSON CONTROLS
Maximum
chilled water
flow rate
GPM (l/s)
860 (54)
860 (54)
1040 (66)
580 (37)
860 (54)
860 (54)
1040 (66)
580 (37)
860 (54)
860 (54)
860 (54)
1040 (66)
1040 (66)
1040 (66)
1040 (66)
1040 (66)
1040 (66)
1040 (66)
1210 (76)
1040 (66)
1040 (66)
1210 (76)
1040 (66)
1210 (76)
1210 (76)

Hide quick links: