A sample of the Operating Data Printout is included.
The operating data printout is a snapshot of current
system operating conditions when the printout was se-
lected. The sample shows combined printouts of 2, 3,
and 4 circuit units. The actual printout will only show
data for the appropriate chiller type.
Bold italic text below a line of print is not
on the actual printout. Bold italic text
indicates information that may not be
available on all printouts or is additional
information to help explain the difference
in a 2/3 or 4 circuit printout.
Operating data printout
YORK INTERNATIONAL CORPORATION
YVAA SCREW CHILLER
OPERATING DATA
2:04:14 PM
SYS 1
NOT RUNNING
SYS 2
COMPRESSOR RUNNING
OPTIONS
CHILLED LIQUID
LOCAL/REMOTE MODE
LEAD/LAG CONTROL
REMOTE TEMP RESET
REMOTE CURRENT LIMIT
REMOTE SOUND LIMIT
(if Sound Limiting enabled)
LOW AMBIENT CUTOUT
PROGRAM VALUES
SUCT PRESS CUTOUT
LOW AMBIENT CUTOUT
LEAVING LIQUID CUTOUT
MOTOR CURRENT LIMIT
PULLDOWN CURRENT LIMIT
PULLDOWN LIMIT TIME
SUBCOOLING SETPOINT
UNIT ID NUMBER
SOUND LIMIT SETPOINT
(if Sound Limiting enabled)
UNIT DATA
LEAVING LIQUID TEMP
JOHNSON CONTROLS
30 DEC 11
WATER
REMOTE
AUTOMATIC
DISABLED
0 TO 10 V
4 TO 20 MA
ENABLED
44 PSIG
25.0 DEGF
36.0 DEGF
100 %FLA
100 %FLA
0 MIN
12.0 DEGF
0
100%
49.0 DEGF
RETURN LIQUID TEMP
TEMP RATE
COOLING RANGE
REMOTE SETPOINT
AMBIENT AIR TEMP
LEAD SYSTEM
FLOW SWITCH
EVAPORATOR PUMP RUN
EVAPORATOR HEATER
ACTIVE REMOTE CONTROL
OPERATING HOURS 1=XXXXX,
START COUNTER 1=XXXXX,
SOFTWARE VERSION
VSD DATA
ACTUAL FREQUENCY
COMMAND FREQUENCY
DC BUS VOLTAGE
INTERNAL AMBIENT TEMP
COOLING SYSTEM STATUS
BASEPLATE TEMPS
PRECHARGE SIGNAL
MOTOR OVERLOADS 1/2
SOFTWARE VERSION
UNIT SERIAL NUMBER
SYSTEM 1 DATA
COMPRESSOR STATUS
RUN TIME
MOTOR CURRENT
SUCTION PRESSURE
DISCHARGE PRESSURE
OIL PRESSURE
CONDENSER LIQUID TEMP
DISCHARGE TEMPERATURE
SAT SUCTION TEMP
SUBCOOLING
SAT DISCHARGE TEMP
DISCHARGE SUPERHEAT
MOTOR TMP
COMPRESSOR SPEED
COND DRAIN % OPEN
ECONOMIZER % OPEN
CONDENSER FANS ON
SECTION 8 - MICROPANEL
58.2 DEGF
XXX.X DEGF/MIN
42.0+/-2.0 DEGF
44.0 DEGF
74.8 DEGF
SYS 2
ON
ON
OFF
NONE
2=XXXXX
2=XXXXX
C.ACS.XX.00
XXX.X HZ
XXX.X HZ
XXX VDC
XXX.X DEGF
XXX
XXX XXX DEGF
XXX
XXX XXX AMPS
C.VSD.XX.00
YYYY XXXZZZ
OFF
0- 0- 0- 0 D-H-M-S
0AMPS
0 %FLA
125 PSIG
131 PSIG
130 PSIG
68.4 DEGF
68.8 DEGF
71.8 DEGF
3.4 DEGF
74.5 DEGF
6.3 DEGF
XXX.XXXX.XXXX.XDEGF
XXX.X %
XXX.X %
XXX.X %
0