6. Other Cautions

6.1

SPG Selecting Conditions

The spindle pulse generator (SPG) connected to this CNC system should satisfy the
following conditions.
Number of pulses
Signal
Type of output
Note:
1)
The number of pulses recommended is 1024 P/R.
2)
Phase A and B signals should be set HIGH only once while the zero point signal
is set HIGH.
Phase A
Phase B
Phase Z
Table 6.1.1
(1024 P/R)
A/B90° phase signal + zero (0) point signal
Line driver output
Fig. 6.1.1
– 99 –
STE 73843