3.6.3

Noise Killer

In the machine and power drive panel, AC/DC solenoid valves, AC/DC relays and
motors are used. At the time of ON/OFF, these can generate pulse voltage of large
energy through inductance of coil, and cause dielectric in cables, etc., giving
disturbance to the electronic circuit.
To reduce this pulse voltage, use a spark killer for AC or a diode for DC.
(1)
DC
+
(2)
AC relay, contactor coil
(3)
3-phase AC induction motor
R
Diode
Fig. 3.6.2
MC
Spark killer
Fig. 3.6.3
3-phase spark killer
Fig. 3.6.4
– 47 –