POWER Module
T9PW2
CNIP
PLC
OUTPUT
MODULE
CN2
NPN1
–3
–1
(Sequence program)
Note:
When this stroke end signal is not used, add 24VDC voltage between Pin A4
and Pin B4 of the T9PW2 CNIP connector.
–A4
Axis 1 (+) Axis 1 (–) Axis 2 (+)
–B4
(Y001)
EMG RESET
pushbutton switch
(H420)
H420
Fig. 6.3.1
POWER Module
T9PW2
CNIP
–A4
–B4
Fig. 6.3.2
Axis 2 (–)
Bypass circuit
This switch has two normal open
contacts. One contact is used for
general-purpose input.
(The other contact is connected
to the emergency reset input.)
+
24VDC
– 107 –
+
+24VDC
Y001
STE 73843