22. While making sure the Feed Roller Plate is level with other end of the scanner is level with the
glass, tighten up the lower T10 screw. Tighten all the remaining lower T10 screws, while still
making sure the Feed Roller Cover is level with the glass plate.
23. Retighten the remaining T10 screw along the Feed Roller cover.
24. Refit the Drive Belt.
25. Refit the OTAC Assy.
26. Adjust the Lid Sensor as shown on page 101.
27. Once the Lid Sensor has been adjusted, refit the Rear Panel.
HD Ultra X Service Guide
Page 79