8.6

Changing the needle seals

Removing the needle seals
1.
Clean the automatic spray gun (
on page 30).
2.
Remove the material needle (
Fig. 15: Unscrewing the screw from the head piece and main element
3.
Unscrew the screw ( Fig. 15/2) from the head piece ( Fig. 15/1) and the main element (
Fig. 153).
4.
Remove the head piece ( Fig. 15/1) from the main element ( Fig. 15/3).
Fig. 16: Removing the needle pack
5.
Unscrew the seal screw ( Fig. 16/3).
6.
Remove all of the needle pack ( Fig. 16/4) from the head piece ( Fig. 16/5).
7.
Remove the seals ( Fig. 16/2) from the centring tubes ( Fig. 16/1).
GB–36
Operating instructions
Ä Chapter 8.3 'Cleaning the automatic spray gun'
Ä Chapter 8.5 'Changing the material needle' on page 33).
T-Dok-700-GB-Rev.0