Changing Needle Seals - Krautzberger RA 5 Operating Instruction

Automatic spray gun
Hide thumbs Also See for RA 5:
Table of Contents

Advertisement

Automatic spray gun RA 5
7.5

Changing needle seals

Removing needle seals
1.
Removing the fluid needle (
Fig. 17: Removing needle seals
2.
Unscrew the clamping screw ( Fig. 17/4) with a box spanner.
3.
Remove the grooved ring ( Fig. 17/5) from the clamping screw ( Fig. 17/4).
4.
Remove the bracket ( Fig. 17/2) and grooved ring ( Fig. 17/1) from the bracket ( Fig. 17/2) .
5.
Check the condition of the O-ring ( Fig. 17/3), replace if necessary.
6.
Replace the grooved rings ( Fig. 17/1 and 5).
Inserting the needle seals
1.
Insert the grooved ring ( Fig. 17/1) into the bracket ( Fig. 17/2). Here, make sure that the
grooved ring ( Fig. 18/1) is in the correct position.
Fig. 18: Installation state
2.
Insert the bracket ( Fig. 17/2) with the grooved ring ( Fig. 17/1) into the main element (
Fig. 17/9) .
3.
Make sure that the O-ring ( Fig. 17/3) fits correctly on the clamping screw ( Fig. 17/4).
4.
Insert the grooved ring ( Fig. 17/5) onto the clamping screw ( Fig. 17/4). Here, make sure
that the grooved ring ( Fig. 18/5) is in the correct position.
5.
Insert the clamping screw ( Fig. 17/4) into the main element ( Fig. 17/9) and tighten with a
box spanner.
200-0319 ■ 200-0321 ■ 200-0323 ■ 200-0324