8.3

Cleaning the automatic spray gun

WARNING!
Risk of injury due to improper cleaning!
Adhere to the safety data sheets of the cleaning product manufacturer.
Do not fully immerse the automatic spray gun in a cleaning product.
1.
Suspend operation (
2.
Switch off the system and secure it against a restart.
3.
Connect cleaning product to material inlet.
For models with circulation connection (optional), connect the material circulation line.
4.
Switch on the compressed air supply.
5.
Where applicable, switch on material pressure pump or pressure container for cleaning
product.
6.
Begin the spray process by switching on the control air (connection "St") and the atomiser
air (connection "Z").
7.
Spray until the cleaning agent runs clear.
8.
Interrupt the supply of the cleaning product.
9.
Blow out the cleaning product residue by briefly switching on the control air.
10.
Switch off the compressed air supply and secure it against a restart.
11.
Clean the outside of the device with a cloth dipped in cleaning product.
12.
Remove material and air nozzle (
nozzle' on page 31) and clean with a soft brush. Do not use hard or sharp-edged objects.
We recommend our brush set. See the last page for contact information.
13.
Slightly grease the sliding parts with special Krautzberger grease.
The special grease can be purchased from Krautzberger GmbH (contact data see last
page).
GB–30
Operating instructions
Ä Chapter 7.6 'Shutting down' on page 27).
Ä Chapter 8.4 'Changing the material nozzle and the air
T-Dok-700-GB-Rev.0