Connecting The Automatic Spray Gun - Krautzberger A 16 Operating Instructions Manual

Automatic spray gun
Table of Contents

Advertisement

Automatic spray gun A 16 / A 16 HVLP
6.5

Connecting the automatic spray gun

Ä Chapter 6.4 'Connection scheme' on page 18).
See also (
WARNING!
Danger of injury due to improper connection!
When the material supply is pressurised, e.g. from pressure containers or with pumps, the
range of the material jet can increase by a multiple in case of atomiser air failure. This
presents a hazard to people and property.
Make sure that the material supply and the control air are interrupted if the atomiser air
pressure drops off quickly.
It is recommended to regulate the atomiser air pressure via a filter pressure reducer.
The connections for control air and atomiser air are marked with letter abbreviations.
Fig. 4: Connecting the automatic spray gun
1.
Connect the control air to input "St" ( Fig. 4/3).
2.
Connect the atomiser air to input "Z" ( Fig. 4/2).
3.
Connect the material line to the reducing nipple ( Fig. 4/1).
Item number: 200-0422 ■ 200-0423
ENGLISH
GB–19