Automatic spray gun A 16 / A 16 HVLP
6.5
Connecting the automatic spray gun
Ä Chapter 6.4 'Connection scheme' on page 18).
See also (
WARNING!
Danger of injury due to improper connection!
When the material supply is pressurised, e.g. from pressure containers or with pumps, the
range of the material jet can increase by a multiple in case of atomiser air failure. This
presents a hazard to people and property.
–
Make sure that the material supply and the control air are interrupted if the atomiser air
pressure drops off quickly.
–
It is recommended to regulate the atomiser air pressure via a filter pressure reducer.
The connections for control air and atomiser air are marked with letter abbreviations.
Fig. 4: Connecting the automatic spray gun
1.
Connect the control air to input "St" ( Fig. 4/3).
2.
Connect the atomiser air to input "Z" ( Fig. 4/2).
3.
Connect the material line to the reducing nipple ( Fig. 4/1).
Item number: 200-0422 ■ 200-0423
ENGLISH