Page 66 of 88 pages
Operation (Option Version)
12.5.2 Pulse Control
When the factor smaller than 1.00 is entered a step-down results, for the
factor larger than 1.00 a step-up takes place.
Factor setting range 0.01 to 9999.
Example table:
The number of strokes executed is equal to the number of incoming pulses
x factor
Factor
Pulses (sequence)
0.01
0.10
0.25
0.33
3.03 (33 • 3 - 1 • 4)
0.40
2.5 (2 - 3)
0.50
0.75
1.33 (1 - 1 - 2)
1.00
1.25
1.50
2.00
2.50
25.0
9999
If one does not obtain an integer result on dividing by the factor, in the
microprocessor the residual amount after the decimal point is added up
and an additional stroke is executed as soon as the result reaches or
exceeds the value 1.
Thus on average for injection operation the precise metering amount
according to the factor results.
With the Pulse Control option the following functions are possible:
-
Pulse step-down with factor 0.01 - 1.00
-
Pulse step-up (preselection) with factor 1.00 - 9999
-
Memory "Mem"
-
Display of the step-down or step-up factor "N÷ "
-
Stroke counter device "N" (also available for Analog variant)
Pulse
Metering strokes (sequence)
100
10
4
2
1
1
1
1
1
1
1
Metering stroke
1
1
1
1
1
1
1
1
1.25 (1 - 1 - 1 - 2)
1.5 (1 - 2)
2
2.5 (2 - 3)
25
9999
Version 2.0