Version 2.0
Operation (Option Version)
Pulse step-down/step-up:
Please note:
The stroking rate set in "Manual" operation results in the max.
stroking rate in "Contact" operation. If no frequency reduction is
desired the max. stroking rate is to be set in "Manual" operation
before switching over to "Contact" operation.
This function enables the number of pulses received to be divided by a
factor of 0.01 to 1.00 or multiplied by 1.00 to 9999.
As a result for example in connection with pulse-type water meters the
pump can be tuned into a process in an optimum manner or be operated
by displaying the step-up factor "N÷ " as predetermining counter.
To set:
P
• Press the
key approx. 2 seconds.
The display
Stop
Manual
Contact
• or
Stop
• Press the
or
selected.
Stop
Manual
Contact
• Confirm with the
• Press the
or
f
N
key until "Manual" and "Contact" can be
P
key.
key until "Contact" appears.
Page 67 of 88 pages