Operation (Basic Version)

12.3.3 Internal "Manual" operation

PLEASE NOTE:
If no float switch or control cable is connected both the function
plugs must remain plugged in at the inputs (11) and (12).
• After the pump is started the yellow pilot light (1) lights up and the
following display appears (factory setting):
Stop
Manual
STOP
• Press the
key.
START
• The pump now operates with the max. stroking rate displayed e.g. 120
strokes per minute.
Manual
• The yellow pilot light (1) goes out for a short moment while the stroke
is being performed.
• With the
set with quartz-like accuracy e.g. 99 strokes per minute.
Manual
• After every change of the stroking rate or when changing the program,
an arrow
in the lower right hand corner of the display flashes for
about five seconds.
• When this period has elapsed the new setting is saved; if the mains plug
is pulled within five seconds the new setting is disregarded.
f
f
keys the desired stroking rate can be precisely
f
Version 2.0