Operation (Basic Version)
Minimum
Contact
If the second stage of the float switch is activated (tank empty) the
metering stops; the yellow pulse/pilot display (1) then lights up continuously,
the error message "Error" appears additionally in the display
Error
Minimum
Contact
PLEASE NOTE:
If single-stage float switches already present should be used,
adapter cables are available as a transition!
Adapter cable with flat connector: order no. 80.83.12.3
ATTENTION:
In order that the correct function (for empty warning "Contact
open") is provided, the float of the single- stage float switch must
be removed from the stay tube and turned by 180 ° !
Before plugging in the 3-pole float cable plug the function plug
must be pulled out from level input (11)!
PLEASE NOTE:
If the float cable plug is pulled out from input (11) or the cable
is disconnected "Error" appears in the display and "Minimum"
flashes; if the option fault annunciation relay is fitted the word
"Relay" also appears.
When the float plug or function plug is connected the alarm
message goes off if there is sufficient fluid!